S100
The S100 are powerful new generation of frequency inverters that can be used in a very wide range of applications, from simple fan and pump drives to complex applications where the controller can replace with build in user sequences. The S100 frequency inverters are available in a classic IP20 enclosure or in an optional IP66 enclosure that allows installation without an electrical box. Dual rating operation makes it possible to choose a class of weaker converter if we have a load with variable torque (pumps, fans). The S100 frequency inverters can operate in v / f mode or as an open-loop vector where it also supports PMAC motors.
V/f
sensorless vector IM
PM motor control
Dual Rating:
Heavy duty: 150% for 60s
Normal duty: 120% for 60s
*Dual Rating is not supported with frequency inverters S100 in IP66 protection.
- STO (Safe Torque Off)
- EMC filter ( C2 for one-phase, C3 for three-phase) and DC choke (for models - power range:30~75kW)
- PID, JOG, 3-wire operation, UP/DOWN, DC braking, Power Braking, User Sequences,…
- Relay and transistor output (optional I/O unit)
- Analog (2 at Multiple I/O option) in pulse output
- Multifunction outputs (5 or 7)
- 2 analog inputs
- Pulse input
- RS-485 and optional communication
The IP20 housing requires installation in an electrical box as it does not offer dust and water protection. This housing is a classic choice that offers a good price-performance ratio for the freqeuncy inverter.
The IP66 housing provides protection against water & dust and allows the installation of a frequency inverter outside the electrical box. With the additional switches, potentiometer or a touch screen, all wiring can be packed in one box. Ideal for pumps, fans and other standalone applications.
Clip marks
P1~P7: multifunction inputs
CM: mass
VR: voltage source 12V (for potentiometer connection)
V1: voltage analog input 1
I2: current/voltage (optional) analog input 2
SA, SB, SC: terminals for STO connection
S+, S-, SG: connector for RS-485 communication
AO1, AO2, AO: analog outputs
TI: pulse input
TO: pulse output
A1, B1, C1: alarm outputs
Q1, EG: transistor outputs
P24: 24V
A2, C2: relay output
RS-485 (standard)
Profibus DB (optional)
Profinet (optional)
Modbus TCP (optional)
EtherCAT (optional)
Ethernet IP (optional)
CANopen (optional)
All S100 frequency inverters have a built-in keyboard. For models up to and including 22 kW, a seven-segment LED keypad is integrated, with the option of installing an external LCD keyboard. For models with a power rating of 30 kW or more, an LCD keyboard is integrated as standard.
The LCD keyboard is standard on S100 frequency inverters with power rating of 30 kW or more. With other models the LCD keyboard can be used as an external option.